TOP GUIDELINES OF DP50RB

Top Guidelines Of Dp50rb

Top Guidelines Of Dp50rb

Blog Article

Support 4D probe; understand the probe by using the ID code; switch the 4D drive signal through the  electrical relay to make the 4D probe perform Commonly. four.2.2 Primary board The key board could possibly be divided into two components: entrance-close of the leading board and back again-conclude of the key board.

one.2.2 Warning Labels Warning Labels Meaning Please cautiously read this manual just before use system. The subsequent labels certainly are a. Usually do not place the machine over a sloped surface area. In any other case the obtainable in the event the technique system may slide, leading to particular harm or maybe the product works While using the mobile malfunction.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

After you prevent the scanning and also the graphic capture, you need to energy from the method and disconnect the technique with the AC electrical power offer, then pull out AC electrical power cables. Web page 109: Battery Connecting Board

Find out improved diagnostic details by extended check out of the anatomical composition on all convex probes.

Reduce off cable ties connecting the main device around the Display screen by diagonal cutting pliers, after which you can pull out the corresponding cable plugs.

Critical specifics of our romance along with you: Consumer Romance Summaries Our Client Romance Summaries give a brief summary of our expert services, charges and obligations once we do the job along with you in the broker-seller or an expenditure advisory marriage.

S. need to offer the Department having an e mail deal with if they've a single. The e-mails offered may be employed for official communication While using the licensee. Having said that e mail addresses are community report. If you do not desire to produce a private address, remember to give the Section with the e-mail handle that may be designed available to the general public. To determine if you are a licensee less than Chapter 455, File.S., please Just click here . Products Acceptance Accepts:

Notice: Ahead of uploading the log, make certain the ultrasound system has been linked to network, usually, the technique may perhaps warn “could not connect to server” The server (smtp.

Just after successful relationship, the recently added community printer title is going to be revealed from the printer driver checklist. Be aware: Just before join the network printer, make certain the ultrasound method and also the printer are in the same network area, as well as the community is Functioning normally. The IP deal with and also the server title should be legitimate, e.g. Web site forty seven DICOM Environment  Enter the AE Title on the ultrasound program, port and PDU in accordance with the true situation, and afterwards simply click [OK] to exit the display.

Web page forty five Return “Printer Company” web site, Choose the corresponding support from your printer list and enhance the assistance. The process integrates drivers of HP printers, after HP printers are related, drivers will be put in instantly (about 10s).If auto set up fails, icon will Screen on the proper lessen corner in the display to alert you that manual installation is important. Webpage forty six: Community Preset

Most four periods tasking for a person transmitted beam, leading to exceptional time resolution and higher body fee.

Just after replacing the CPU module, essential file need to be generated once again in accordance with the new MAC deal with and written into HDD of your machine. Or else, the configuration purpose with the product or service are going to be dropped. Just after taking away the CPU module, Take away panhead screws with washers (12 M3X6) fastened on the leading unit box, you can take from the board. Site 118 Determine eight-29 Disassemble the Control Panel Assembly (one) Hold the higher fringe of user interface assembly, and open up up the control panel. Determine eight-30 Disassemble the Control Panel Assembly (two) Just after eradicating one particular countersunk head self-tapping screw PT3X10 fixed on the user interface and consider out the plug from the keyboard and the primary unit connecting cables, you could clear away the user interface assembly.

Performance Check 5.5.one Take a look at Approach Resolution Detection depth Geometric Posture Precision Blackout area test File the exam images 5.five.two Check Written content The image applied Here's just for reference, stick with the picture influence in the actual Take note: circumstance. Necessities: Display screen: established the distinction and brightness within the scientific software worth (or perhaps the default status) Operation environment: darkish place, simulating the scientific application ecosystem. Web page 76 In ailment the transverse resolution testing targets are horizontally shown, document the minimal length of two targets which can be clearly acknowledged. Repeat the operation earlier mentioned with the transverse resolution testing targets at other depths. As proven in figure under. Axial resolution ... Web site 77 When using the convex probe, preserve the transverse resolution screening targets to NOTE: be displayed close to the midline. When utilizing a linear probe with steer functionality, don't activate the steer functionality when accomplish the transverse resolution examination. Zoom during the area exactly where the targets Positioned if needed. The diameter in the target stage at a particular depth is equal into the transverse resolution for the depth. Website page 78 5.

Simply click Concur and Move forward to accept cookies and go directly to the positioning or click on More Information to see thorough descriptions of the categories of cookies and select no matter whether to accept certain cookies though on the location.

5.2.3 Geometric positioning accuracy Longitudinal geometric positioning precision  Take a look at Stage: Do adjustments as the best way in screening the maximum depth. Record the distance by 20mm Each and every phase on the longitudinal targets line utilizing the measurement caliper; Pick the value with the greatest error (to 20mm), compute the precision using the method down below The measurement caliper should be positioned with the higher edge of the target, Notice:... Page 79 Transverse geometric positioning accuracy  Exam Move: Include the scan surface area of your phantom with drinking water or pair gel, gently Get hold of Dp50rb login the probe Along with the scan floor Modify the depth, making the transverse targets to be displayed within the picture. Regulate the main target level to generally be posited beside the transverse targets (the conventional is not really very clear) Change parameters like obtain, TGC, creating Every transverse targets being clearly shown. Website page 80 five.five.2.4 Blackout Location Test Stage: Include the scan area of the phantom with h2o or few gel, Carefully Call the probe With all the scan surface area Change the depth in a lessen value, and set the main focus at the closest destination to the scan area. Minimize the worth of parameters like AP, Obtain until finally the qualifications noise just can be observed. Site eighty one: Software package Upgrade And Maintenance

Report this page